What is the WHMIS classification?
According to the Commission des normes, de l'équité, de la santé et de la sécurité du travail (CNESST), sulfuric acid can be classified as:
Acute toxicity - inhalation - Category 2
Skin corrosion/irritation - Category 1
Serious eye damage/eye irritation - Category 1
The signal word is danger.
The hazard statements are:
CNESST comments: This product could be corrosive to metals, please contact the supplier for additional information.
Please note that this classification was retrieved from the CNESST site on
February 22, 2023and was established by CNESST personnel to the best of their knowledge based on data obtained from scientific literature and it incorporates the criteria contained in the Hazardous Products Regulations (SOR/2015-17). It does not replace the supplier’s classification which can be found on its Safety Data Sheet.
- context Corrosive to the respiratory tract. Fatal if inhaled
- context Causes severe skin burns and eye damage
What Personal Protective Equipment (PPE) is needed when working with sulfuric acid?
Eye/Face Protection: Wear chemical safety goggles and face shield when contact is possible.
Skin Protection: Wear chemical protective clothing e.g. gloves, aprons, boots. Suitable materials (sulfuric acid 30-70%) include: butyl rubber, natural rubber, neoprene rubber, polyvinyl chloride (PVC), Viton®, Viton®/butyl rubber, AlphaTec® (02-100, 4000, EVO, VPS), Kemblok®, Silver Shield® - PE/EVAL/PE, Saranex®™, Chemprotex® 300, ChemMAX® 3, Tychem® 6000.
Respiratory Protection:
Up to 15 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*; or Any powered, air-purifying respirator with acid gas cartridge(s) in combination with a high-efficiency particulate filter*.
(APF = 50) Any chemical cartridge respirator with a full facepiece and acid gas cartridge(s) in combination with an N100, R100, or P100 filter; or Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted acid gas canister having an N100, R100, or P100 filter; or Any self-contained breathing apparatus with a full facepiece; or Any supplied-air respirator with a full facepiece.
*Causes eye irritation or damage; eye protection needed.
APF = Assigned Protection Factor
Recommendations apply only to National Institute for Occupational Safety and Health (NIOSH) approved respirators. Refer to the NIOSH Pocket Guide to Chemical Hazards for more information.