What is a confined space?
Generally speaking, a confined space is a fully or partially enclosed space that:
Confined spaces can be found in almost any workplace. Confined spaces can be below or above ground. A confined space, despite its name, is not necessarily small. Examples of confined spaces include silos, vats, hoppers, utility vaults, tanks, water supply towers, sewers, pipes, access shafts, truck or rail tank cars, aircraft wings, boilers, manholes, pump stations, digesters, manure pits and storage bins. Ditches, wells, and trenches may also be confined spaces when access or egress is limited (but they still have “blue sky” above). Barges, shipping containers and fish holds are also considered as possible confined spaces.
- context is not primarily designed or intended for continuous human occupancy
- context has limited or restricted entrance or exit, or a configuration that can complicate first aid, rescue, evacuation, or other emergency response activities
- context its design, construction, location or atmosphere
- context the materials or substances in it
- context work activities being carried out in it, or
- context the mechanical, process and safety hazards present
- context can represent a risk for the health and safety of anyone who enters, due to one or more of the following factors:
Why is working in a confined space more hazardous than working in other workspaces?
Many factors need to be evaluated when looking for hazards in a confined space. There is a smaller margin for error. An error in identifying or evaluating potential hazards can have more serious consequences. In some cases, the conditions in a confined space are always extremely hazardous. In other cases, conditions are life threatening under an unusual combination of circumstances. This variability and unpredictability are why the process of hazard and risk identification and assessment is extremely important and must be taken very seriously each and every time one is done.
Some examples include:
- safety The entrance or exit of the confined space might not allow the worker to get out easily should there be a flood or collapse of free-flowing solid.
- general Self-rescue by the worker is more difficult.
- safety Rescue of the victim is more difficult. The interior configuration of the confined space often does not allow easy movement of people or equipment within it.
- safety Natural ventilation alone will often not be sufficient to maintain breathable quality air. The interior configuration of the confined space does not allow easy movement of air within it.
- general Conditions can change very quickly.
- safety The space outside the confined space can impact the conditions inside the confined space and vice versa.
- general Work activities may introduce hazards that were not present initially.
- general Lack of communication between the workers in the space, the attendant and the emergency response team.
What should be done when preparing to enter the confined space?
The important thing to remember is that each time a worker plans to enter any work space, the worker should determine if that work space is considered a confined space. Be sure the confined space hazard assessment and control program has been followed. Please see the OSH Answers document Confined Space - Program for more information.
The next question to ask is - Is it absolutely necessary that the work be carried out inside the confined space? In many cases where there have been deaths in confined spaces, the work could have been done outside the confined space!
Before entering any confined space, a trained and experienced person should identify and evaluate all the existing and potential hazards within the confined space. Evaluate activities both inside and outside the confined space.
Air quality testing: The air within the confined space should be tested from outside of the confined space before entry into the confined space. Care should be taken to ensure that air is tested throughout the confined space - side-to-side and top to bottom. Continuous monitoring should be considered in situations where a worker is in a space where atmospheric conditions have the potential to change (e.g., broken or leaking pipes or vessels, work activities create a hazardous environment or isolation of a substance is not possible). A trained worker using detection equipment which has remote probes and sampling lines should do the air quality testing. Always ensure the testing equipment is properly calibrated and maintained. The sampling should show that:
The results of the tests for these hazards are to be recorded on the Entry Permit along with the equipment or method(s) that were used in performing the tests.
Air testing is often ongoing, depending on the nature of the potential hazards and the nature of the work. Conditions can change while workers are inside the confined space and sometimes a hazardous atmosphere is created by the work activities in the confined space.
For more information see our OSH Answers document on Confined Space - Atmospheric Testing.
- requirement The oxygen content is within safe limits - not too little and not too much.
- requirement A hazardous atmosphere (toxic gases, flammable atmosphere) is not present.
- engineering Ventilation equipment is operating properly.
How are fire and explosion prevented?
Work where a flame is used or a source of ignition may be produced (hot work) should not normally be performed in a confined space unless:
While doing the hot work, the concentrations of oxygen and combustible materials must be monitored to make sure that the oxygen levels remain in the proper range and the levels of the flammable products or combustible materials do not get higher than the prescribed Lower Explosive Limits in your jurisdiction. In special cases, it may not be possible, and additional precautions must be taken to ensure the safety of the worker prior to entering the confined space.
If potential flammable atmosphere hazards are identified during the initial testing, the air in the confined space should be cleaned or purged, ventilated and then tested again before entry to the confined space is allowed. Only after the air testing is within allowable limits should entry occur as the gases used for purging can also be extremely hazardous.
- requirement Keep the concentration of any explosive or flammable hazardous substance to a level that does not create an explosion hazard, for example less than 5% or 10% of its Lower Explosive Limit (These numbers can vary slightly from jurisdiction to jurisdiction.) AND
- requirement Make sure that the oxygen content in the confined space is not enriched. Oxygen content should be less than 23% but maintained at levels greater than 19.5%. (These numbers can vary slightly from jurisdiction to jurisdiction.)
- engineering All flammable gases, liquids and vapours are removed before the start of any hot work. Mechanical ventilation is usually used to
- requirement Surfaces coated with combustible material should be cleaned or shielded to prevent ignition.
- requirement Do not bring fuel or fuel containers into the confined space (e.g., gasoline, propane), if possible. Ensure welding equipment is in good condition.
- requirement Where appropriate, use spark-resistant tools, and make sure all equipment is bonded or grounded properly.
What are other safety precautions?
Many other situations or hazards may be present in a confined space. Be sure that all hazards and risks are identified and controlled, for example:
- context Any liquids or free-flowing solids should be removed from the confined space to eliminate the risk of drowning or suffocation.
- context All pipes should be physically disconnected or isolation blanks bolted in place. Closing valves is not sufficient.
- context Use two blocking valves, with an open vent or bleed valve between the blocking valves when isolating pipelines or similar conveyances to prevent entry of materials and hazardous contaminants.
- context A barrier is present to prevent any liquids or free-flowing solids from entering the confined space.
- context The opening for entry into and exit from the confined space must be large enough to allow the passage of a person using protective equipment.
- context Making sure no work is being performed outside of the space that could impact the safety or air quality inside the confined space.